Materials | |
Name | Specification |
Compressor Oil - Air Conditioning | WSH-M1C231-B / 6U7J-M1C231-AA |
Removal
NOTE: Removal steps in this procedure may contain installation details.
1. Refer to: Air Conditioning (A/C) System Recovery, Evacuation and Charging (412-00 Climate Control System - General Information, General Procedures).
CAUTION: Make sure that all openings are sealed. Use new blanking caps.
Torque: 8 Nm
3. Refer to: Lifting (100-02 Jacking and Lifting, Description and Operation).
CAUTION: Make sure that all openings are sealed. Use new blanking caps.
Torque: 20 Nm
Installation
1. To install, reverse the removal procedure.
2. Coat the O-ring seals on the refrigerant lines.
Material: Compressor Oil - Air Conditioning (WSH-M1C231-B / 6U7J-M1C231-AA) refrigerant oil