General Equipment
Ford approved diagnostic tool
Pneumatic Vacuum Gun
Materials
Name | Specification |
Metal Adhesive Kit - 2 Component | WSK-M2G342-A / 2U7J-M2G400-AA |
Removal
1. Refer to: Hydraulic Control Unit (HCU) (206-09 Anti-Lock Control - Stability Assist, Removal and Installation).
3. Clean the HCU contact surface.
Material: Metal Adhesive Kit - 2 Component (WSK-M2G342-A / 2U7J-M2G400-AA) cleaner 4. Remove all traces of the cleaner and foreign material.
General Equipment: Pneumatic Vacuum Gun
Installation
WARNING: Make sure that the module is correctly located on the hydraulic control unit (HCU).
CAUTION: If accidentally dropped or knocked install a new hydraulic control unit (HCU) and module.
Take extra care not to damage the seal.
NOTE: Make sure that the seal is correctly located.
Torque: 5,5 Nm
2. Refer to: Hydraulic Control Unit (HCU) (206-09 Anti-Lock Control - Stability Assist, Removal and Installation).
3. Configure the stability assist program.
General Equipment: Ford approved diagnostic tool
4. Carry out the stability assist program Function Test.
General Equipment: Ford approved diagnostic tool
5. Carry out a road test.
Refer to: Road/Roller Testing (100-00 General Information, Description and Operation).