Toyota
Ford Kuga
 Service Manual
Climate Control
Blower Motor - RHD(34 374 0)

Special Tool(s)

Removal

NOTE: Removal steps in this procedure may contain installation details.

1. Refer to: Cowl Panel Grille (501-02 Front End Body Panels, Removal and Installation).

2. Torque: 25 Nm

Blower Motor - RHD(34 374 0)

3. Refer to: Steering Column (211-04 Steering Column, Removal and Installation).

4. Refer to: Floor Console Extension - Vehicles With: Center Armrest (501-12 Instrument Panel and Console, Removal and Installation).

Blower Motor - RHD(34 374 0)

6. Torque: 25 Nm

Blower Motor - RHD(34 374 0)

Blower Motor - RHD(34 374 0)

Blower Motor - RHD(34 374 0)

Blower Motor - RHD(34 374 0)

Blower Motor - RHD(34 374 0)

CAUTION: Make sure that the blower motor and fan assembly is placed on the bench with the fan pointing upwards.

Special Tool(s): 412-131

Blower Motor - RHD(34 374 0)

Installation

1. NOTE: The component can only be installed in 1 position.

To install, reverse the removal procedure.

    More about «Climate Control»:

    Condenser

    Clutch and Clutch Field Coil

    Pollen Filter - RHD

    Blower Motor - RHD(34 374 0)

    Blower Motor Resistor - Vehicles With: Manual Temperature Control, RHD(34 382 0)

    Blower Motor Resistor - Vehicles With: Dual Automatic Temperature Control(34 382 0)

    Heater Core and Evaporator Core Housing

    Heater Core - RHD(34 364 0)

    Suction Accumulator

    Suction Accumulator to Air Conditioning (A/C) Compressor Line

    Suction Accumulator to Air Conditioning (A/C) Compressor Line - 2.5L Duratec (147kW/200PS) - VI5

    Low-Pressure Cutoff Switch

    High-Pressure Cutoff Switch

    Evaporator

    Evaporator Outlet Line

    Evaporator Core Orifice

    Condenser to Evaporator Line

    Climate Control Assembly - Vehicles With: Manual Temperature Control(34 300 0)

    Climate Control Assembly - Vehicles With: Automatic Temperature Control(34 300 0)

    Footwell Air Discharge Temperature Sensor(34 485 4)

    Center Register Air Discharge Temperature Sensor

    In-Vehicle Temperature Sensor

    Footwell Vent/Duct Blend Door Actuator - RHD(34 591 0)

    Air Inlet Blend Door Actuator(34 606 0)

    Driver Side Temperature Blend Door Actuator(34 608 0)

    Passenger Side Temperature Blend Door Actuator(34 608 0)

    Defrost Vent/Register Blend Door Actuator - RHD(34 591 0)

    Ford Kuga Service Manual / Climate Control / Blower Motor - RHD(34 374 0)

    Ford Kuga Service Manual

    Main Categories


    © 2017-2024 Copyright www.fokuman.com
    0.0089